Show status (general status of unit)
Show gps (GPS information)
Show inventory
See
Backing up Provisioning

Enabling Outputs

Enter the following command to set the interface state.
Example for port 5:
Set interface state port 5 enable

Setting The Output To Test Mode

Enter the following command to set the interface test mode.
Example for port 9:
Set interface test-mode port 9 enable

Configuring For Default Mode (Real Time Clock)

Enter the following commands to set the TOD source to RTC"
Set tod-source rtc
Sync tod-source now

Configuring For User Mode

Enter the following command to set the clock in user mode:
Set tod-source user
Example to set the clock in user mode:
Set clock date 2006-05-20 time 10:23:00
Sync tod-source now

Configuring For GPS Mode

Enter the following commands to the TOD source to GPS:
097-93100-01 Revision C – February, 2010
Chapter 4 General Guidelines for using the Symmetricom TimeCreator 1000
Data, on page 110 for additional details.
CLI commands