Show TOD-Source
This command displays the Time Of Day Source.
Command Syntax:
show tod-source
Example:
tc1000>show tod-source
Related:
sync tod-source, set tod-source
Level :
User, Power-User and Admin
Set TOD-Source
Use this command to provision the TOD Source for GPS, DTI client port, NTP
server, or the local Real-Time Clock.
Command Syntax:
set tod-source {gps|dti|ntp|rtc|user}
Example:
To set the TOD source to GPS:
tc1000>set tod-source gps
Related:
sync tod-source, show tod-source
Level :
Power-User and Admin only
Note: If the system has passed the warm up state, the Sync
TOD-Source command is also required.