Symmetricom TimeCreator 1000 User Manual page 60

Docsis timing interface server
Hide thumbs Also See for TimeCreator 1000:
Table of Contents

Advertisement

Chapter 3 Installing the TimeCreator 1000
Applying Power to the TimeCreator 1000
Table 3-5. Module LED Descriptions (Continued)
LED
Power
GPS
Alarm
Ethernet
Connection
Ethernet Activity
Ext Ref
Power
Alarm
Active
Holdover
Output
60
TimeCreator 1000 User's Guide
Color
IMC Module
Off
Module power fault
Green
Module power is functioning properly
Off
System is not provisioned to use GPS reference
Amber
GPS input is enabled but GPS input has not been
qualified as reference
Green
System is provisioned to use GPS reference and GPS
reference is qualified as reference
Off
There are no alarms being generated by the system
Red
There are alarms being generated by the system
Off
No Ethernet link established
Green
Ethernet link established
Off
No Ethernet activity
Amber
Blinks with Ethernet activity
IOC Module
Off
System is not provisioned to use external references
Amber
System is provisioned to use external references, but
at least one of the reference inputs has been
disqualified from being selected as system reference
Green
System is provisioned to use external reference(s)
and all reference inputs are qualified as possible
system references
Off
Module power fault
Green
Module power is functioning properly
Off
There are no alarms being generated by IOC
Module's components, Input, Outputs, Clocks, etc.
Red
There are alarms being generated by IOC Module's
components, Input, Outputs, Clocks, etc.
Off
Module is in Standby Mode
Green
Module is in Active Mode, output source
Off
Module is not in Holdover
Amber
Module is in Holdover
Off
DTI output error or port is in standby mode
Green
All DTI server ports are operating normally
Description
097-93100-01 Revision C – February, 2010