Timecreator Events Traps - Additional Details - Symmetricom TimeCreator 1000 User Manual

Docsis timing interface server
Hide thumbs Also See for TimeCreator 1000:
Table of Contents

Advertisement

Appendix A Alarms, Events and SNMP Traps
SNMP Traps
.
Table A-9. TimeCreator Events Traps - Additional Details
OID
Trap OID Name
Index
(y)
1
trapIOCReset
(id = 1)
2
trapIOCFirmwareCopy
Fail
(id = 5)
3
trapIOCActive
(id = 6)
4
trapIOCStandby
(id = 7)
5
trapIOCWarmup
(id = 8)
162 TimeCreator 1000 User's Guide
Description
IOC <#> Module
trapID:
reboot
trapAID1: 1 or 2,
trapAID2: n/a
trapState:
trapValue: n/a
Firmware copy
trapID:
bwtween IOC
trapAID1: n/a
modules failed
trapAID2: n/a
trapState:
trapValue: n/a
IOC <#> is the
trapID:
active IOC module
trapAID1: 1 or 2,
IOC <#> is not
active IOC module
trapAID2: n/a
trapState: clear (1),
trapValue: n/a
IOC <#> is the
trapID:
standby IOC module
trapAID1: 1 or 2,
IOC <#> is not
standby IOC module
trapAID2: n/a
trapState: clear (1),
trapValue: n/a
IOC <#> has
trapID:
transitioned in to
trapAID1: 1 or 2,
Warm-up Mode
trapAID2: n/a
trapState:
trapValue: n/a
Bindings
IOCRST
IOC module id
set (2)
COPYFAIL
set (2)
CARDACTV
IOC module id
set (2)
CARDSTBY
IOC module id
set (2)
CLKWARM
IOC module id
set (2)
097-93100-01 Revision C – February, 2010
Severity
nonalarm
nonalarm
nonalarm
nonalarm
nonalarm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents