Electrical installation
9.3.3

24 VDC supply (X01)

The supply connection X01 is used for supplying the supply modules of the AX8000 with 24 V
voltage.
Safe operation
When connecting motors with holding brake it is essential to observe the voltage toler-
ances.
CAUTION
X01 – input terminal AX8620
Input terminal
Terminal point
24 VDC
GND
X02 – input terminal AX8640
Input terminal
Terminal point
24 VDC
GND
Commissioning
Commissioning of the AX8000 is only possible if the terminal points "R
bridged (delivery state) or an external brake resistor is connected to the terminal points "R
Note
+" and "R
B
48
All manuals and user guides at all-guides.com
Connection
24 V
±10%
DC
System and
peripheral voltage
GND
Connection
24 V
±10%
DC
System and
peripheral voltage
GND
-". Without this measure the AX8000 is stopped with an error message.
Version: 1.0
Max. wire cross-
Tightening torque
section
2
6 mm
(AWG 8)
0.5 – 0.6 Nm
(4.4 – 5.3 lbf in)
Max. wire cross-
Tightening torque
section
2
16 mm
(AWG 6)
1.2 – 1.5 Nm
(10.6 – 13.3 lbf in)
+" and "R
bin´