12.1.4

Product identification

Type key
Infographic
1)
recommended connecting cable: ZK4000-2101-2xxx (1.5 mm²)
2)
recommended connecting cable: ZK4000-2102-2xxx (2.5 mm²)
12.1.5

Mechanical installation

12.1.5.1
Mounting positions and distances
(A) = vertical installation is only permitted according to the diagram (terminal box facing downwards).
(B) = horizontal installation
For all mounting positions the following minimum distances must be adhered to:
200 mm to adjacent components, walls, etc. and 300 mm to components, ceilings, etc. located above. In the
case of vertical mounting (A), a distance of 200 mm must be maintained to components located underneath
to ensure that air can flow without hindrance to the brake resistor.
AX8000 - system manual
All manuals and user guides at all-guides.com
Version: 1.0
Item no. Description
1
Drive Technology Accessories
2
BR = brake resistor
3
Servo drives from the AX8000 series
4
1000 = AX8620-1000 and AX8640-0000, 1 kW,
1)
18 Ω
1600 = AX8620-0000, 1.6 kW, 33 Ω
2000 = AX8640-1000, 2.0 kW, 18 Ω
3200 = AX8640-0000, 3.2 kW, 18 Ω