11.5

Control cabinet

The dimensions of the control cabinet must be sufficient to accommodate all components with the specified
distances. Remember that high temperatures may necessitate forced cooling. Position the control cabinet as
close as possible to the machine so that the motor cables can be as short as possible. In addition, the
control cabinet should have an earthed metal rear panel to which the AX8000 incl. periphery are attached so
that safe earthing can be guaranteed. If you are unable to guarantee these conditions you need to earth the
AX8000 and the relevant components using an approved cable of adequate size.