Start-up Options

Desktop Access

Software Support

Table 2 - PanelView Plus 6 Software Support
Software
FactoryTalk View Machine Edition Station
FactoryTalk View Studio for
Machine Edition
FactoryTalk ViewPoint
(700 to 1500 terminals only)
Windows CE 6.0 OS
You can configure the terminal to perform one of three actions at startup:
• Launch a FactoryTalk View Machine Edition HMI application.
• Launch the FactoryTalk View Machine Edition Configuration mode of
the terminal where you load and run applications, configure start-up
options and terminal settings, and enable or disable desktop access.
• Launch the Windows Explorer desktop.
The factory default state and start-up option following a firmware upgrade is to
launch the terminal in Configuration mode. Refer to
page 51
for details on how to change the start-up option.
Any of the terminals can be configured to allow or restrict desktop access. From
the desktop, you can perform system and control panel operations, or run
third-party applications. Terminals with optional, extended features (catalog
numbers ending in 9) can additionally run viewers, media players, and launch the
web browser. You can even allow access temporarily to perform specific tasks,
then disable desktop access to prevent unauthorized changes.
TIP
Refer to
Desktop Access on page 54
IMPORTANT
The table lists software supported on the terminals.
Description
Runtime environment for FactoryTalk View Machine Edition .mer applications. Machine Edition
Station is preloaded on each terminal and does not require FactoryTalk View activation.
Configuration software for developing HMI applications that run on PanelView Plus 6 terminals.
®
RSLinx
Enterprise software is included with FactoryTalk View Studio software and loaded during
installation.
Add-on capability provided with FactoryTalk View Studio software:
• This web-based, thin-client solution lets manufacturers or casual users monitor or download
changes to a running Machine Edition application from remote locations via an Internet
browser.
• A single license is embedded with each terminal supporting a single client connection to
terminal. No additional software is required.
Operating system that runs on all terminals.
Rockwell Automation Publication 2711P-UM006E-EN-P - January 2017
All terminals are initially shipped with desktop access disabled.
for details on how to modify desktop access.
Desktop access does not change the feature set of your terminal. If you have a
terminal with a catalog number ending in 8, opening the desktop does not
give you access to extended features and file viewers.
Overview
Chapter 1
Start-up Options on
Version
• 6.10 or later
(400 and 600 terminals)
• 6.0 or later
(700 to 1500 terminals)
1.2 or later
6.0
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents