Allen-Bradley PanelView Plus 6 User Manual
Hide thumbs Also See for PanelView Plus 6:

Advertisement

Quick Links

User Manual
Original Instructions
PanelView Plus 6 Compact Terminals
Catalog Numbers 2711PC-K4M20D8, 2711PC-B4C20D8, 2711PC-B4C20D8-LR, 2711PC-T6M20D8, 2711PC-T6C20D8,
2711PC-T10C4D8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PanelView Plus 6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allen-Bradley PanelView Plus 6

  • Page 1 User Manual Original Instructions PanelView Plus 6 Compact Terminals Catalog Numbers 2711PC-K4M20D8, 2711PC-B4C20D8, 2711PC-B4C20D8-LR, 2711PC-T6M20D8, 2711PC-T6C20D8, 2711PC-T10C4D8...
  • Page 2 Important User Information Read this document and the documents listed in the additional resources section about installation, configuration, and operation of this equipment before you install, configure, operate, or maintain this product. Users are required to familiarize themselves with installation and wiring instructions in addition to requirements of all applicable codes, laws, and standards.
  • Page 3: Table Of Contents

    Software Support ..........10 PanelView Plus 6 Compact Applications ......10 Product Selections .
  • Page 4 Table of Contents System Information ..........62 Enable or Disable the Alarm Display .
  • Page 5 Table of Contents Chapter 7 Firmware Upgrades Terminal Firmware ..........133 Download Firmware Files.
  • Page 6 Table of Contents Notes: Rockwell Automation Publication 2711PC-UM002F-EN-P - February 2020...
  • Page 7: Preface

    Topic Pages Updated the power supply catalog number. 14, 26 Firmware Upgrades For the latest firmware upgrades and other downloads for PanelView Plus 6 Compact terminals, go to http://www.rockwellautomation.com/support click Firmware Updates. Additional Resources These documents contain additional information concerning related products from Rockwell Automation.
  • Page 8 Preface Notes: Rockwell Automation Publication 2711PC-UM002F-EN-P - February 2020...
  • Page 9: Overview

    Desktop Access Product Accessories PanelView™ Plus 6 Compact terminals (400/600/1000) are similar to the PanelView Plus 6 (400/600) terminals but with limited hardware and software functions. Major differences of the PanelView Plus 6 Compact terminals include the following items: • Serial and Ethernet communication only •...
  • Page 10: Software Support

    Display FactoryTalk View ME Station Information on page 64 for a list of ActiveX controls loaded on a terminal. PanelView Plus 6 Compact PanelView Plus 6 Compact Machine Edition applications are restricted to a subset of the functions on the PanelView Plus 6 terminals: Applications •...
  • Page 11: Terminal Features

    Chapter 1 Overview Terminal Features The PanelView Plus 6 Compact 400, 600, and 1000 terminals are fixed configurations that do not support modular components. Table 3 - PanelView Plus 6 Compact Terminal Components Item Component 3.5, 5.7, or 10.4-in. grayscale or color display with one of these operator input options: •...
  • Page 12: Operator Input

    Chapter 1 Overview Operator Input The terminals feature grayscale or color LCD displays with keypad, touch screen, or keypad and touch-screen input. Table 4 - Display and Operator Input Features Item Feature Description Product label Product identification label can be replaced with custom label. Color or grayscale display with or without a resistive, 4-wire, touch screen (catalog Display/touch screen number dependent)
  • Page 13: Open Versus Closed System

    Chapter 1 Overview Open versus Closed System The terminals can be configured to run an open or closed desktop environment: • An open system launches the Windows Explorer desktop on startup. The system is configurable via the control panel and supports Windows operations.
  • Page 14: Product Accessories

    Chapter 1 Overview Product Accessories Table 5 through Table 10 lists accessories for the terminals. Table 5 - Secure Digital (SD) Cards Cat. No. Terminal Model Description 1784-SD1 1 GB SD card 1784-SD2 All terminals 2 GB SD card 2711C-RCSD USB to SD adapter for SD card Table 6 - Cables Cat.
  • Page 15: Install The Terminal

    Chapter Install the Terminal Topic Page Required Circuit Parameters for USB Peripheral Devices Mounting Clearances Panel Guidelines Panel Cutout Dimensions Product Dimensions Mount the 400/600 Terminal in a Panel Mount the 1000 Terminal in a Panel Remove and Install the Power Terminal Block DC Power Connections Initial Startup Reset Terminal...
  • Page 16: Hazardous Locations

    Chapter 2 Install the Terminal ATTENTION: Wiring and Safety Guidelines Use publication NFPA 70E, Electrical Safety Requirements for Employee Workplaces, IEC 60364 Electrical Installations in Buildings, or other applicable wiring safety requirements for the country of installation when wiring the devices. In addition to the NFPA guidelines, here are some other guidelines to follow: •...
  • Page 17 Per the National Electrical Code, the circuit parameters of associated field-wiring apparatus for use in hazardous locations must be coordinated with the host product such that their combination remains nonincendive. PanelView Plus 6 Compact terminals and the USB peripheral devices must be treated in this manner.
  • Page 18: Mounting Clearances

    Chapter 2 Install the Terminal Mounting Clearances Plan for adequate space around the terminal, inside the enclosure, for ventilation and cabling. Consider heat produced by other devices in the enclosure. The ambient temperature around the terminal must be 0…55 °C (32…131 °F). Table 12 - Minimum Required Clearances Product Area Minimum Clearance...
  • Page 19: Product Dimensions

    Figure 4 provide product dimensions. Figure 2 - PanelView Plus 6 Compact - 400 Keypad or Keypad/Touch Figure 3 - PanelView Plus 6 Compact - 600 Touch Figure 4 - PanelView Plus 6 Compact - 1000 Touch Table 14 - PanelView Plus 6 Compact - 400/600/1000 Product Dimensions...
  • Page 20: Mount The 400/600 Terminal In A Panel

    Chapter 2 Install the Terminal Mount the 400/600 Terminal The terminals are designed for single-person installation. No tools are required except for those needed to make the panel cutout. in a Panel Four mounting levers secure the terminal to the panel. The levers insert into the mounting slots on the top and bottom of the terminal.
  • Page 21 Chapter 2 Install the Terminal 3. Place the terminal in the panel cutout. 4. Insert all mounting levers into the mounting slots on the terminal. Slide each lever until the flat side of the lever touches the panel surface. Flat Side of Lever Mounting Levers Mounting Slots 5.
  • Page 22: Mount The 1000 Terminal In A Panel

    Chapter 2 Install the Terminal Mount the 1000 Terminal in a Four mounting clips secure the 1000 terminal in a panel. Tools required for installation include panel cutout tools, a small, slotted screwdriver, and a torque Panel wrench for tightening the mounting clips. ATTENTION: Disconnect all electrical power from the panel before making the panel cutout.
  • Page 23 Chapter 2 Install the Terminal 3. Place the terminal in the panel cutout. Mounting Clip Mounting Clip Slot 4. Slide the ends of the mounting clips into the slots on the terminal. 5. Tighten the mounting clip screws by hand until the gasket seal contacts the mounting surface uniformly.
  • Page 24: Remove And Install The Power Terminal Block

    Chapter 2 Install the Terminal Remove and Install the The terminals are shipped with a power terminal block installed. You can remove the terminal block for ease of installation, wiring, and maintenance. Power Terminal Block WARNING: Explosion Hazard If you connect or disconnect wiring while the power is on, an electrical arc can occur.
  • Page 25 Chapter 2 Install the Terminal 2. Gently push the top of the terminal block to rotate it into place. The terminal block snaps into place when seated. 1000 Terminals Follow these steps to remove the terminal block from a 1000 terminal. 1.
  • Page 26: Dc Power Connections

    The 400 and 600 terminals require a dedicated 24V DC Class 2 power supply or a safety extra-low voltage (SELV) or protective extra-low voltage (PELV) power supply to power each PanelView Plus 6 Compact 400 or 600 device. For the 1000 terminals, it is recommended that a dedicated 24V DC safety extra- low voltage (SELV) or protective extra-low voltage (PELV) power supply is used to power each PanelView Plus Compact 6 1000 device.
  • Page 27 Install the Terminal Earth/Ground Connection PanelView Plus 6 compact terminals use a DC power input and have an earth/ ground terminal that you must connect to a low-impedance earth/ground: • On 400 and 600 terminals, the earth/ground connection is on the power terminal block.
  • Page 28 Chapter 2 Install the Terminal Connect DC Power WARNING: Explosion Hazard Do not disconnect equipment unless power has been switched off and area is known to be nonhazardous. Disconnect all power before installing or replacing components. Failure to disconnect power can result in electrical shock or damage to the terminal. Follow these steps to connect the terminal to DC power.
  • Page 29: Initial Startup

    Chapter 2 Install the Terminal Initial Startup The first time you start the system, the terminal goes through its power-up sequence and launches FactoryTalk® View ME Station Configuration mode. You can change the action the terminal takes on startup by pressing Terminal Settings then choosing Startup Options.
  • Page 30: Access Configuration Mode

    Chapter 2 Install the Terminal After a restart, the terminal performs a series of start-up tests then takes one of these actions: • Launches an HMI application that is configured to run at startup. • Launches FactoryTalk ME Station Configuration mode. •...

Table of Contents