Cycle Parameters - HEIDENHAIN TNC 620 User Manual

Cnc
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

17
Touch Probe Cycles: Special Functions
17.3
MEASURING IN 3-D (Cycle 4, software option 17)

Cycle parameters

Parameter number for result: Enter the number
of the Q parameter to which you want the TNC
to assign the first measured coordinate (X). The
values Y and Z are in the immediately following Q
parameters. Input range: 0 to 1999
Relative measuring path in X: X component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Relative measuring path in Y: Y component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Relative measuring path in Z: Z component of the
direction vector defining the direction in which the
touch probe is to move. Input range -99999.9999 to
99999.9999
Maximum measuring path: Enter the maximum
distance from the starting point by which the touch
probe may move along the direction vector. Input
range -99999.9999 to 99999.9999
Feed rate for measurement: Enter the measuring
feed rate in mm/min. Input range 0 to 3000.000
Maximum retraction distance: Traverse path in the
direction opposite the probing direction, after the
stylus was deflected. Input range 0 to 99999.9999
Reference system? (0=ACTUAL/1=REF): Define
whether the probing result should be saved in the
input coordinate system (ACTUAL) or referenced to
the machine-table coordinate system (REF):
0: Save the measured result in the ACTUAL system
1: Save the measured result in the REF system
422
NC blocks
4 TCH PROBE 4.0 MEASURING IN 3-D
5 TCH PROBE 4.1 Q1
6 TCH PROBE 4.2 IX-0.5 IY-1 IZ-1
7 TCH PROBE 4.3 DIST+45 F100 MB50
REFERENCE SYSTEM:0
TNC 620 | User's Manual Cycle Programming | 3/2014

Advertisement

Table of Contents
loading

Table of Contents