16
Touch Probe Cycles: Automatic Workpiece Inspection
16.10 MEASURE RIDGE WIDTH (Cycle 426, DIN/ISO: G426, software
option 17)

Cycle parameters

1st meas. point 1st axis Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
1st meas. point 2nd axis Q264 (absolute):
Coordinate of the first touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
2nd meas. point 1st axis Q265 (absolute):
Coordinate of the second touch point in the
reference axis of the working plane. Input range
-99999.9999 to 99999.9999
2nd meas. point 2nd axis Q266 (absolute):
Coordinate of the second touch point in the minor
axis of the working plane. Input range -99999.9999
to 99999.9999
Measuring axis Q272: Axis in the working plane in
which the measurement is to be made:
1: Reference axis = measuring axis
2: Minor axis = measuring axis
Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to SET_UP (touch probe table). Input
range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Nominal length Q311: Nominal value of the length
to be measured. Input range 0 to 99999.9999
Maximum dimension Q288: Maximum permissible
length. Input range 0 to 99999.9999
Minimum dimension Q289: Minimum permissible
length. Input range 0 to 99999.9999
Measuring log Q281: Define whether the TNC
should create a measuring log:
0: Do not create a measuring log
1: Create a measuring log: The TNC saves the
file TCHPR426.TXT
TNC:\.
2: Interrupt program run and output measuring log
to the TNC screen. Resume program run with NC
Start.
402
as standard in the directory
NC blocks
5 TCH PROBE 426 MEASURE RIDGE
WIDTH
Q263=+50
Q264=+25
Q265=+50
Q266=+85
Q272=2
Q261=-5
Q320=0
Q260=+20
Q311=45
Q288=45
Q289=44.95;MINIMUM DIMENSION
Q281=1
Q309=0
log
Q330=0
TNC 620 | User's Manual Cycle Programming | 3/2014
;1ST POINT 1ST AXIS
;1ST POINT 2ND AXIS
;2ND POINT 1ST AXIS
;2ND POINT 2ND AXIS
;MEASURING AXIS
;MEASURING HEIGHT
;SET-UP CLEARANCE
;CLEARANCE HEIGHT
;NOMINAL LENGTH
;MAXIMUM DIMENSION
;MEASURING LOG
;PGM STOP IF ERROR
;TOOL