HEIDENHAIN TNC 620 User Manual page 397

Cnc
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

MEASURE RECTANGLE OUTSIDE (Cycle 424, DIN/ISO: G424,
Tolerance for center 1st axis Q279: Permissible
position deviation in the reference axis of the
working plane. Input range 0 to 99999.9999
Tolerance for center 2nd axis Q280: Permissible
position deviation in the minor axis of the working
plane. Input range 0 to 99999.9999
Measuring log Q281: Define whether the TNC
should create a measuring log:
0: Do not create a measuring log
1: Create a measuring log: The TNC saves the
file TCHPR424.TXT
TNC:\.
2: Interrupt program run and output measuring log
to the TNC screen. Resume program run with NC
Start.
PGM stop if tolerance error Q309: Definition of
whether in the event of a violation of tolerance
limits the TNC is to interrupt program run and output
an error message:
0: Do not interrupt program run, do not output an
error message
1: Interrupt program run and output an error
message
Tool for monitoring Q330: Definition of whether
the TNC is to monitor the tool (see "Tool
monitoring", page 378). Input range 0 to 32767 .9,
alternatively tool name with maximum of 16
characters
0: Monitoring inactive
>
0: Tool number in the tool table TOOL.T
TNC 620 | User's Manual Cycle Programming | 3/2014
as standard in the directory
software option 17)
Q279=0.1
Q280=0.1
Q281=1
Q309=0
Q330=0
log
16.8
;TOLERANCE 1ST
CENTER
;TOLERANCE 2ND
CENTER
;MEASURING LOG
;PGM STOP IF ERROR
;TOOL
397
16

Advertisement

Table of Contents
loading

Table of Contents