HEIDENHAIN TNC 620 User Manual page 350

Cnc
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

15
Touch Probe Cycles: Automatic Datum Setting
15.8 DATUM FROM OUTSIDE OF CORNER (Cycle 414, DIN/ISO: G414,
software option 17)
Execute basic rotation Q304: Definition of
whether the TNC should compensate workpiece
misalignment with a basic rotation:
0: Do not execute basic rotation
1: Execute basic rotation
Datum number in table Q305: Enter the datum
number in the datum or preset table in which the
TNC is to save the coordinates of the corner. If
you enter Q305=0, the TNC automatically sets the
display so that the new datum is on the corner.
Input range 0 to 2999
New datum for reference axis Q331 (absolute):
Coordinate in the reference axis at which the TNC
should set the corner. Default setting = 0. Input
range -99999.9999 to 99999.9999
New datum for minor axis Q332 (absolute):
Coordinate in the minor axis at which the TNC
should set the calculated corner. Default setting = 0.
Input range -99999.9999 to 99999.9999
Measured-value transfer (0, 1) Q303: Specify
whether the determined datum is to be saved in the
datum table or in the preset table:
-1: Do not use! Is entered by the TNC when old
programs are read in (see "Characteristics common
to all touch probe cycles for datum setting",
page 322)
0: Write determined datum in the active datum
table. The reference system is the active workpiece
coordinate system
1: Write the measured datum into the preset table.
The reference system is the machine coordinate
system (REF system).
Probe in TS axis Q381: Specify whether the TNC
should also set the datum in the touch probe axis:
0: Do not set the datum in the touch probe axis
1: Set the datum in the touch probe axis
Probe TS axis: Coord. 1st axis Q382 (absolute):
Coordinate of the probe point in the reference axis
of the working plane at which point the datum is
to be set in the touch probe axis. Only effective if
Q381 = 1. Input range -99999.9999 to 99999.9999
350
Q332=+0
;DATUM
Q303=+1
;MEAS. VALUE
TRANSFER
Q381=1
;PROBE IN TS AXIS
Q382=+85
;1ST CO. FOR TS AXIS
Q383=+50
;2ND CO. FOR TS AXIS
Q384=+0
;3RD CO. FOR TS AXIS
Q333=+1
;DATUM
TNC 620 | User's Manual Cycle Programming | 3/2014