ANALYZE Area
The details provide the Date and Time the event occurred.
Source – Shows where the user changed the values. Controller means the keypad was used, aTB means the Alpha
Toolbox was used.
Details – Shows which part of the controller the changes were made.
Press the BACK interactive menu button to return the LOG screen.
Press the MANAGE interactive menu button to export Log Data to the USB memory stick or to clear the event log.
Connect a USB memory stick to the USB port on the bottom of the Alpha controller. Use the up/down arrows and/
or the numeric keypad to select option.
Use the up/down arrows and/or the numeric keypad to type a file name. Pressing the OK interactive menu button
saves the data to the USB memory stick.
After the file is saved, press the OK button to return to the LOG screen.
Press the MANAGE interactive menu button to clear the data.
Press OK to clear the data or press CANCEL to return to the LOG screen.
Press YES to clear the data, NO to return to the LOG screen.
Use the right arrow to move to the next tab or press EXIT to save the changes and return to the Run screen. See
section "3.1.2.6 Exit" on page 52.

3.3.5 I/O Tab

This tab indicates the real time status of the 24V DC Inputs and Outputs. Forcing the I/O on or off is also performed
here. Users must have DIAGNOSTICS or ADMINISTRATOR access level to force I/O.
Each 24V DC connector pin is represented. Pin A is for supplying 24V DC to the I/O functions. Pin V is the
24VDC Return to complete the current loop. Pin B is the bus for the Outputs. See section "6.11 Input and Output
Connector" on page 116 for a schematic. Pins L through U are for Inputs. Pins C through K are for Outputs. See
section "3.1.4.3 I/O Tab" on page 69 to assign functions to the pins.