QPM Tool Controls and Operation

To install an accessory or bit , fully insert the accessory. The accessory is locked into place.
To remove an accessory, pull the chuck collar away from the front of the tool. Remove the accessory.
5.1.7.2
Square Drive
To Avoid Injury:
• Use only industrial or grade impact accessories. Other grade accessories may break and cause a hazardous
condition. Inspect accessories prior to use to ensure that it con tains no cracks.
• Inspect square drives and detent pins prior to use. Missing or damaged items should be replaced before use.
Remove power or air before changing accessories.
To install an accessory on the square drive, align the hole in the side of the accessory with the detent pin on the
anvil square drive. Press the accessory on until the detent pin engages in the hole. Depression of detent pin may
be necessary to aid installation of the accessory.
To remove an accessory, depress the detent pin through the hole and pull the accessory off.
5.1.7.3
Suspension Devices
Tool suspension devices or bails help support the weight of the tool during tightening operations. If needed,
attach these devices securely and periodically inspect them for damage or loosening.

5.1.8 Cable Installation

ELECTRICAL HAZARD
To Avoid Injury:
• Never use a tool with a damaged cable.
• Never abuse a cable, carry a tool by its cable, hang a tool by its cable, or pull on a cable to disconnect it
from the tool or the controller.
To ensure superior performance and safe operation, use the STANLEY cables specifically designed to operate
these tools.
Never use a tool with a damaged cable. Never abuse a cable, carry a tool by its cable or pull a cable to disconnect
it. Also, keep the cord away from heat, sharp edges, or moving parts.
Use cables of appropriate length (60M maximum) for each application; position and or suspend them in such a
way as to prevent tripping and cable damage, and to provide good work area maneuverability.
5.2
QPM Tool Controls and Operation

5.2.1 Start Trigger Switch

The trigger switch is used to start the tool in either direction. The speed of the tool is programmable in the
controller, not the trigger switch. It is not a variable speed trigger. The trigger switch function is on or off. Press
the start trigger switch to start the tool. Release the start trigger switch to allow the tool to stop.

5.2.2 Tool Memory

QPM tools have an on board tool memory that stores tool identification, calibration factors and fastening cycle
counters. Memory parameters include: