SETUP Area
Automap
The Alpha controller has no default I/O on the Profibus bus. The I/O must be assigned before a GSD file can be
obtained. See Section "3.1.4.3 I/O Tab" on page 69 to assign and configure the Profibus I/O.
3.1.3.9.4.1
GSD Button
Press the GSD interactive menu button to create a GSD file equivalent to the Profibus I/O map created.
Connect a USB memory stick to the USB port on the bottom of the Alpha controller. Use the up/down arrows and/
or the numeric keypad to type a file name or use the default.
Pressing the OK interactive menu button saves the file to the USB memory stick. Use this controller generated GSD
file in the PLC connected to the Alpha controller.
If the Profibus I/O map is changed, a new GDS file must be generated.
Use the right/ left arrow to move to the next tab or press EXIT to save the changes and return to the Run screen.
See section "3.1.2.6 Exit" on page 52.

3.1.4 OTHER Menu

This area sets the parameters for all other Alpha features, including: system level, users, passwords, I/O and tool
functions. Each category is represented by its own tab. Use the left/right arrows to select the tabs/category for
modification.
Users must have ADMINISTRATOR or SETUP access level to modify values in this area.
3.1.4.1
General Tab
Lock Keypad
Name
66
Determines whether or not the Alpha controller will automatically select which type of
I/O modules to setup based on the assignable I/O created in section "3.1.4.3 I/O Tab" on
page 69. If NO is selected the user must enter the I/O modules manually.
Type the number of modules desired. The modules will be created.
Output
User must select the number of BYTES or WORDS that make up each
Modules
module and if it has consistency or not.
Type the number of modules desired. The modules will be created.
User must select the number of BYTES or WORDS that make up each
Input Modules
module and if it has consistency or not.
If YES is selected the Alpha will create the I/O modules. User must select if Consistency is
desired or not. NO will select without consistency, YES will select with consistency.
In Alpha Toolbox only. When YES is selected the Alpha controllers keypad cannot be used
to edit any parameters. It will allow the user to navigate through the system and view
any parameters. If the keypad is locked and it is desired for it to be unlocked one must
connect to Alpha Toolbox on the controller and set this parameter to No. If set to NO the
keypad on the Alpha controller can be used to edit parameters.
A name distinguishes this controller from other Alpha controllers on the same plant floor.
Use the up/down arrows to type letters. Use the numeric keypad to type numbers. This
is also the main Machine ID for PFCS protocol. This value will also be used to label any
files exported via the USB port or Alpha Toolbox. There is a 15 character limit for this
parameter.