Messages - Stanley QB Expert Instruction Manual

Table of Contents

Advertisement

Messages

Temperature Fault!
Unrecognized Tool!
Tool Communications!
Transducer Current Fault!
Unsupported Tool!
Servo Connection Fault!
Spindle Communications The lead controller loses communications with a trailing spindle controller.
2.9
Messages
Messages appear on the screen when certain non-critical conditions exist. They may appear on any screen at any
time.
Communication Fault
Count Fault
Program Fault
Tool Update Failed
PLC Message
Invalid PLC File
Identifying Spindle
26
This fault is asserted when the tool temperature detector has reached the
temperature limit set by the Temperature Limit parameter. It resets after detected
temperature has dropped by 5°C.
The controller is communicating to the tool but does not recognize the model
number written in the tool memory board.
The controller is not communicating to a tool.
Transducer current has fallen outside nominal values. For EA, EB and EC series
tools that is 4.16 mA +/- 75% (1 to 7mA).
The wrong tool type has been connected to the controller. The Alpha controller
cannot run the tool that is connected.
The CPU has lost communication to the DSP on the Logic board. This may
happen on a reboot after and upgrade as the CPU resets before the DSP.
Used for Toyota PI protocol only. Controller has lost communications to the PI
box.
Used for Toyota PI protocol only. Controller and PI box have a bolt count
mismatch.
Used for Toyota PI protocol only. More Fastening cycles were performed than the
PI box expected.
Controller failed to update the tool configuration.
A user defined message controlled by the internal PLC.
Appears when an invalid PLC file is imported into the controller.
Appears when the Expert is identifying a trailing spindle when the trailing
spindle connects or when the interactive IDENTIFY button is pressed.