Icons identify events [1], see list below. Displays last torque and angle readings with units, when a tool is connected
[2]. Up/down arrows next to the torque or angle value indicate the last fastening cycle NOK status whether it
exceeded (up) or did not achieve (down) torque or angle limits.
Identifies the active Job [6] and active Task [7]. Identifies Target batch count [3] and Accumulated bolt count [4]
for the active Job. The side scroll bar indicates events are available in the Event Log. Press the down arrow to
view the events. The number of fastening cycle attempts indicator is below the bolt count box. The run screen
displays unless other programming functions [5] are in use. A Shutoff code is also displayed when applicable [8].
The display also has the current time [10] for the specified region and fastening cycle history in the Fastening cycle
Log [9].
This [11] portion of the screen changes to an orange bar with white background when either Limit Rejects or Job
Timer parameters are used. The orange bar increments in one division of the width equal to the Reject Count value
each time a NOK cycle occurs. This bar also acts as a progress bar for the Job Timer to indicate the progress of
the timer.
The time display [10] will change in the following manner:
When a Part ID is received the time will change to the Part ID for 5 seconds and then return to the clock.
If the Job or Task has been selected the Job Name:Task Name appear on the screen until the batch count (Job) has
been completed and then returns to the clock.
The display background color turns red in the event of a fault; see section "2.8 Faults" on page 25.
The run display changes to indicate the step in which the tool stopped (providing it did not stop during the audit
step).
The Fastening Cycle Log [9] lists the fastening cycles that have occurred in the QB Expert Alpha controller. While
viewing the Run Display press the down arrow to access the Fastening Cycle Log.
Use the up/down arrow keys to scroll through the data listed chronologically (newest at the top, oldest at the
bottom). Each line identifies a fastening cycle. The first column indicates the fastening cycle status or shutoff
code. The second column indicates the achieved torque during the fastening cycle. The third column indicates the
achieved angle during the fastening cycle. The fourth column indicates the working bolt count.

2.7.7 Fastening Cycle Log

Press the interactive MANAGE button after selecting a data line to display the MANAGE dialog box.