The barcode input monitors inter-character timing. When there is a 500 msec gap between characters, a complete
barcode is assumed. When received, the controller logs it with all fastening cycles until another barcode is received
or until the controller power is cycled. If the incoming barcode is longer than 32 characters, then the last 32
characters received are used.
6.4

Serial Connector

Alpha controllers have one male DB-9 connector. The setup is 9600-baud rate, 8 data bits, No Parity and 1 Stop
bit, and is not programmable except with the PLC. The connection between a device such as a computer and the
controller is a null-modem cable.
Communication functions can be selected for the serial port. See section "3.1.3.3 Serial Tab" on page 50.
Pin
1
Carrier Detect
2
Receive Data
3
Transmit Data
The controller uses only pins 2, 3, and 5.
Fastening Cycle String:
S01,JB01,  4.1,A,126.2,A,A,06/09/2008 10:20:19,                                ,
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    |    
  |    job number
  spindle number (1=LEADING, 2=TRAILING)
Instruction Manual
DB-9 Connector Pins
Function
Pin
Function
4
Data Terminal Ready
5
Signal Ground
6
Data Set Ready
| |     |
| |  |  |    | 
| |     |
| |  |  |    | 
| |     |
| |  |  |    | 
| |     |
| |  |  |    | 
| |     |
| |  |  |    | 
| |     |
| |  |  |    year
| |     |
| |  |  day
| |     |
| |  month
| |     |
| overall status (A=OK, R=NOK)
| |     |
angle status (A=OK, H=HIGH, L=LOW)
| |     angle result (last step ran or audit step whichever is smaller, fixed decimals)
| torque status (A=OK, H=HIGH, L=LOW)
torque result (last step ran or audit step whichever is smaller, decimals are tool/units dependant)
Pin
Function
7
Request to Send
8
Clear to Send
9
Ring Indicator
|  |  |                       |
|  |   |                       barcode (32 characters)
|  |  second
|  minute
hour