After you enter this command, messages such as the following appear at the destination specified for debugging
output. You can turn off these messages with the no debug ip bgp dampening command.
BGP: (1.1.1.1) dampening - route down 3.3.3.0/24
Old Dampening: state was <*>, reuse_list_index=38, penalty=929, time=48,
flaps=1
New state <h>, penalty=1893, reuse_list_index=43, offset=44
BGP: (1.1.1.1) Dampening - Route 3.3.3.0/24 up
State was <h>, penalty=1893, time=390, flaps=2
New state <*> penalty=1396, reuse_list_index=82, curr_offset=83
BGP: (1.1.1.100) Free Dampening 3.3.3.0/24
Total number of IP routes: 1
Start index: 1
Destination
1
1.1.1.0
Syntax: [no] debug ip bgp dampening
Possible values: N/A
Default value: N/A
debug ip bgp events
Displays messages when BGP-related events occur. BGP-related events include starting or stopping a peer and
opening or closing a BGP TCP connection.
EXAMPLE:
ProCurveRS# debug ip bgp events
After you enter this command, messages such as the following appear at the destination specified for debugging
output. You can turn off these messages with the no debug ip bgp events command.
BGP: 3.3.3.1 start peer
BGP: 3.3.3.1 stop peer
BGP: 3.3.3.1 BGP-TCP Connection opened
BGP: 3.3.3.1 TCP_OPEN done
BGP: 3.3.3.1 keep alive timer expired
Syntax: [no] debug ip bgp events
Possible values: N/A
Default value: N/A
debug ip bgp in
Displays BGP inbound information.
EXAMPLE:
ProCurveRS# debug ip bgp in
After you enter this command, messages such as the following appear at the destination specified for debugging
output. You can turn off these messages with the no debug ip bgp in command.
BGP: rcvd message KEEPALIVE_MESSAGE from peer 1.1.1.100, length (incl. header) 19
BGP: rcvd message UPDATE from peer 1.1.1.100, length (incl. header) 27
BGP: rcvd message OPEN_MESSAGE from peer 1.1.1.100, length (incl. header) 29
Syntax: [no] debug ip bgp in
June 2005
B:BGP D:Connected
R:RIP
NetMask
255.255.255.0
HP Diagnostic Command Reference
S:Static
O:OSPF *:Candidate default
Gateway
Port
0.0.0.0
1
Cost
Type
1
D
3 - 9
Need help?
Do you have a question about the 9304m and is the answer not in the manual?
Questions and answers