Firepower 8000 Series Devices
Table 2-10
Firepower 82xx Family and Firepower and AMP 83xx Family Physical and Environmental Parameters
Parameter
Acoustic noise
Operating shock
Airflow

Firepower 8000 Series Modules

The sensing interfaces for the Firepower 8000 Series appliances can be delivered with copper or fiber
interfaces.
Modules are not hot-swappable. See
Caution
for more information.
The following modules contain configurable bypass sensing interfaces:
The following modules contain non-bypass sensing interfaces:
In addition, you can use a stacking module to connect two Firepower 8140, up to four Firepower 8250,
or up to four Firepower or AMP 8350 devices to combine their processing power and increase
throughput. See
Firepower 8000 Series Hardware Installation Guide
2-12
Description
Max normal operating noise is 81.6 dB LWAd (high temperature).
Typical normal operating noise is 81.4 dB LWAd.
No errors with half a sine wave shock of 2G (with 11 ms duration)
3
Front to back, 210 ft
(6 m
Restriction of the airflow such as blocking the front or back or enclosing the unit in a cabinet
without sufficient clearance may cause the unit to overheat, even if the ambient temperature is in
the operating range.
Airflow through the appliance enters at the front and exits at the rear. The minimum
recommended clearance in the front and back is 7.9 in. (20cm). This minimum can only be used
if you can ensure a supply of low temperature air at the front of the appliance.
a quad-port 1000BASE-T copper interface with configurable bypass capability. See
1000BASE-T Copper Configurable Bypass NetMod, page
a quad-port 1000BASE-SX fiber interface with configurable bypass capability. See
1000BASE-SX Fiber Configurable Bypass NetMod, page 2-13
a dual-port 10GBASE (MMSR or SMLR) fiber interface with configurable bypass capability. See
Dual-Port 10GBASE (MMSR or SMLR) Fiber Configurable Bypass NetMod, page 2-15
information.
a dual-port 40GBASE-SR4 fiber interface with configurable bypass capability (2U devices only).
See
Dual-Port 40GBASE-SR4 Fiber Configurable Bypass NetMod, page 2-16
a quad-port 1000BASE-T copper interface without bypass capability. See
Copper Non-Bypass NetMod, page 2-18
a quad-port 1000BASE-SX fiber interface without bypass capability. See
Fiber Non-Bypass NetMod, page 2-18
a quad-port 10GBASE (MMSR or SMLR) fiber interface without bypass capability. See
10GBASE (MMSR or SMLR) Fiber Non-Bypass NetMod, page 2-19
Stacking Module, page 2-20
3
) per minute
Inserting and Removing Firepower 8000 Series Modules, page B-1
for more information.
for more information.
for more information.
Chapter 2
Hardware Specifications
Quad-Port
2-13.
Quad-Port
for more information.
for more information.
Quad-Port 1000BASE-T
Quad-Port 1000BASE-SX
for more information.
for more
Quad-Port

Advertisement

Table of Contents
loading

Table of Contents