BelAir100SN Installation Guide

AC Power

May 18, 2010

Figure 2: BelAir100SN Ground Point

Ground terminal
through 1/4 inch
screw
Ground point
through cable
connector and shield
The BelAir100SN accepts power in the range of 40 VAC to 90 VAC (-0% to
+10%) from a quasi-square wave cable UPS power supply. The BelAir100SN
also requires that the cable UPS power supply limits its output current to 30 A.
Installers must ensure that the supplied power meets these requirements.
The BelAir100SN contains a permanently attached female KS threaded power
interface (Corning Gilbert part number G-EXT-1.5-SC-T). This connector can
connect with an industry standard GRS KS male threaded connector to accept
cables of the following sizes: 0.412, 0.500, 0.625, 0.750, 0.875 and 1.000 inches.
The mating connector accepts 0.065-inch to 0.75-inch pins trimmed to
0.5 inches.
Figure 3
shows the female KS connector.
Confidential
Document Number BDTK11001-A01 Preliminary
Infrastructure Requirements for the BelAir100SN
Page 7 of 75