RX SX 125
Voltage regulator check
•
Output voltage 13.5 V - 15 V
•
Output current higher than 10 A (with
load)
Turn signals system check
Turn indicator device check
Check placing the tester probes on the poles:
+ / - 5.8 kOhm.
- / L (bulb) 5.3 kOhm.
- / L (bulb) 4.8 kOhm.
•
Undo and remove the screw and re-
move the protection glass with caution
so as not to break the fitting tooth.
•
Slightly press the bulb and turn it anti-
clockwise.Take out the bulb from its
fitting.
•
Upon replacement, insert a bulb of
equal rating in the bulb holder, making
the two guiding pins coincide with their
guides on the bulb holder.
Electrical system
ELE SYS - 59