Control Data; Flywheel Check; Recharge Check; Voltage Regulator - APRILIA SX 125 Service Station Manual

Hide thumbs Also See for SX 125:
Table of Contents

Advertisement

Electrical system
1. Instrument panel
2. Key switch
3. fuses
4. Battery

5. Voltage regulator

6. Generator

Recharge check

Start the engine and make it run at 6000 rpm.
Connect a tester in voltmeter function to check the direct current on the battery leads.
Turn on the low-beam lights.
The voltage must be between 13.5 and 15 V.
Troubleshooting
Check that the fuses are in good conditions.
Check the starter button.
Check the start-up relay.
Check the starter motor.

Control data

Flywheel check

Disconnect the alternator cable con-
nector.
Start the engine and make it run at
5000 rpm.
With the pocket tester measure the
voltage (alternating current) among the
three yellow cables. If the value indica-
ted by the tester is below 53 V, the
generator is faulty.
Standard off-load voltage: above 53 V (AC) at
6000 rpm.
ELE SYS - 58
RX SX 125