Characteristic
Standard spark plug
NGK BR8ES
Standard spark plug (FULL POWER)
NGK R BR10ES
Electrode gap
0.7 - 0.8 mm (0.027 - 0.031 in)
Troubleshooting
Check that the 7.5 A fuse and 20 A fuse are not damaged.
Check the spark plug and replace it if necessary.
Check the high voltage wire and the spark plug cap.
Check the coil.
Check the pick-up.
Check that the 15 A fuses are in good conditions.
Check the diode.
Check the start-up relay.
Replace the CDI by another one in proper operating conditions.

Battery recharge circuit

System diagram key:
Electrical system