Yamaha XVS6501997 Service Manual page 291

Table of Contents

Advertisement

S Start the engine and accelerate to about
5,000 r/min.
Charging voltage:
14 V at 5,000 r/min
NOTE:
Use a fully charged battery.
EB804012
4. Stator coil resistance
S Disconnect the AC magneto coupler from
the wire harness.
S Connect the pocket tester (Ω
tor coils.
Tester (+) lead ! White terminal
Tester (–) lead ! White terminal
Tester (+) lead ! White terminal
Tester (–) lead ! White terminal
S Measure the stator coil resistance.
Stator coil resistance:
0.50 X 0.62 Ω at 20_C
EB804015
5. Wiring connections
S Check the connections of the entire charg-
ing system.
Refer to "CIRCUIT DIAGRAM".
Replace the rectifier/regulator.
OUT OF
SPECIFICATION
1) to the sta-
1
2
1
3
BOTH MEET
SPECIFICATION
CORRECT
CHARGING SYSTEM
MEETS SPECIFICATION
The charging circuit is not faulty.
OUT OF SPECIFICATION
Replace the stator coil assembly.
POOR CONNECTION
Properly connect the charging system.
7-23
ELEC