Operating Environment & Workspace - ProJet 1000 User Manual

Table of Contents

Advertisement

Operating Environment & Workspace
CAUTION! Do not install the printer in the same area as equipment that produces heavy electrical power, heavy vibration, or
airborne contaminants that may adversely affect the performance of the printer.
Air Conditioning
The printing process can be temperature-sensitive within certain limits. Room or environmental ambient operating temperature should be
maintained within a range of from 18°C to 28°C (64°F to 82°F); optimally approximately 23°C (73°F). VisiJet® Printing Materials should be
within this temperature range before use.
Storage Requirements for Part Materials
Room Temperature Controls
Operating Temperature
Non-Condensing Relative Humidity
Noise
NOTE: When planning the work area and to allow unobstructed access to the side panels when replacing parts, refer to the
dimensions listed.
3D Systems recommends that multiple printers should NOT be located on a single electrical circuit. Each location of the machine requires a
standard wall power outlet, RJ-45 network connection and 122cm (4 ft.) power cord supplied with the accessory kit.
IMPORTANT: Do not damage or discard any packaging materials and cartons. If the printer needs to be returned to the manufacturer, it
should be shipped in its original packaging. If other packaging is used, the customer will be responsible for any shipping damages that
may occur.
Heating, ventilation and air conditioning per office building code requirements
18°C to 28°C (64°F to 82°F)
< 30%-50%
< 60 dBa measure 1 m from the printer