High Voltage Potential & Electrical Safety
High
If the electrical module is in need of repair, power down the modeler and unplug the power supply. Remove the side
Voltage
panel, then loosen the 10-32 screw and pull out the electronics tray. This will give access to the PC and Ebox (see
Potential
Electric Module Assembly Installation Instructions). Do not remove the PC cover, doing so will void warranty and
contractual agreements.
Electrical
Safety
Double
Pole/Neutral
Fusing
To operate the printer, the doors (front door and cartridge door on side) must be closed.
This printer requires a grounded, 1-phase electrical power source with a service rating of 100 to 240 VAC~,
50/60 Hz, 5 A (max.). For more detail information, see
A fuse is used in neutral of single-phase equipment with permanently connected or provided with a
non-reversible plug.
After operation of the fuse, parts of the equipment that remain energized might represent a hazard during
servicing.