11 INSTRUCTIONS AND FUNCTIONS
11 - 282
Format 2 control table
%(0)
• • • • • •
Format 2 control table
%(1)
• • • • • •
Specify the network number of the network to be accessed.
See Section 4.2.2 for the allowable specification range.
%(2)
• • • • • •
Specify the station number of the PLC CPU to which data is
written.
See Section 4.2.2 for the allowable specification range.
%(3)
• • • • • •
Detailed error codes are stored here.
See Appendix 4.4.2 for the details about the error codes.
%(4)
• • • • • •
Processing code
%(5)
• • • • • •
Specify the device number of the extension file registers
expressed in sequential addresses.
%(6)
• • •
%(7)
• • • • • •
Specify the number of device points to be written, including
the device specified in %(5) and %(6).
The allowable specification range is from 1 to 64 points.
• Specify 256.
• Specify 7.
MELSEC-Q