11 INSTRUCTIONS AND FUNCTIONS
Processing Code 4
11 - 271
Writing to extension file registers
Control table format definition
Element position
Format 1
Format 2
%(0)
• • • • • • •
%(0)
%(1)
%(2)
%(3)
%(1)
%(4)
%(2)
%(5)
%(3)
%(6)
%(4)
%(7)
• It is possible to write data to extension file registers (file registers with block
number 1 or greater) using this code.
• Specify the following data for <control table>.
Format 1 control table
%(0)
• • • • • •
%(1)
• • • • • •
%(2)
• • • • • •
%(3)
• • • • • •
%(4)
• • • • • •
Item
Station number
Control table
Network number
Station number
Detailed error code
Processing code
Block number
Device number
Number of points
Specify the station number of the PLC CPU to which data is
written.
See Section 4.2.2 for the allowable specification range.
Processing code
• Specify 4.
Specify the block number of the extension file registers.
• If 0 is specified for the block number, data is written to
the file registers of the PLC CPU.
(This is the same processing as writing to R by
writing device memory.)
• If a number greater than 0 is specified for the block
number, data is written to the extension file registers.
• The maximum value that can be specified for the block
number varies depending on the memory cassette
mounted on the PLC CPU.
Specify the device number of the extension file registers.
The maximum value that can be specified for the device
number is the value set in the parameters of the PLC CPU.
Specify the number of device points to be written, including
the device specified in %(3).
The allowable specification range is from 1 to 64 points.
MELSEC-Q
Description
Specify the station number of the PLC.
Specify a control table of format 2.
Specify the network number.
Specify the station number of the PLC.
Detailed error codes are stored here.
Specify the processing code.
Specify the block number of the
extension file registers.
Specify the device number of the
extension file registers.
Specify the number of points to be written.
11 - 271