10 Program Debugging
10
10- 2
(2) STOP and CONT instructions and operation of the Break ( Ctrl
+ C ) key
The program pauses (interrupts) when a STOP instruction is executed.
Also, if the Break ( Ctrl + C ) key is pressed while the program is being
executed, the program pauses (interrupts) in the same way as in the case of the
STOP instruction.
Execute the CONT instruction to resume the execution of a program that has
been paused (from the next instruction).
10 C=1
20 FOR I%=0 TO 3
30 PRINT I%
40 NEXT I%
50 PRINT "Count = ";C
60 STOP
70 C=C+1
80 GOTO 20
MELSEC-Q
RUN
0
1
2
3
Count = 1
Break in 60
OK
CONT
0
1
2
3
Count = 2
Break in 60
OK
If additions, modifications, or
deletions are made to a program
while it is paused, the execution
cannot be resumed using the
CONT instruction.