MSI Code
Usage:
Used in retail and inventory markets.
Definition:
A variation of Plessey, MSI is a numeric, continuous code, with each char-
acter consisting of four bits in a binary format.
MSI Status
Serial Cmd:
<K486,
mum symbol length>
Default:
Disabled
Options:
0 = Disabled
Check Digit Mode (MSI Code)
Serial Cmd:
<K486, status,check digit
mum symbol length>
Default:
Mod10
Check Digit Output Status (MSI Code)
Serial Cmd:
<K486,
tus,unused,minimum symbol length>
Default:
Enabled
Options:
0 = Disabled
Minimum Symbol Length (MSI Code)
Definition:
Specifies a number of characters that the reader will recognize, including
a check digit character.
Serial Cmd:
<K486,
mum symbol
Default:
6
Options:
0 to 32
Zero equals any length. 1 through 32 sets a minimum length.
status,check digit mode,check digit output status,unused,mini-
1 = Enabled
mode,check digit output status,unused,mini-
status,check digit
mode,check digit output sta-
1 = Enabled
status,check digit mode,check digit output
length>