Code 93
Usage:
Used occasionally in clinical industry.
Definition:
Code 93 is a variable length, continuous symbology employing four ele-
ment widths. Each Code 93 character has nine modules that may be
either black or white. Each character contains three bars and three
spaces.
Code 93 Status
Serial Cmd:
<K475,
Default:
Disabled
Options:
0 = Disabled
Minimum Symbol Length (Code 93)
Usage:
Minimum Symbol Length helps prevent truncations and increases data
integrity by ensuring that a minimum symbol length will be accepted.
Definition:
Specifies the minimum number of characters that the reader will recog-
nize (this does not include start and stop and check digit characters). The
reader ignores any symbol smaller than the specified length.
Important: When setting Symbol Length to any number other than
zero, add
has
Serial Cmd:
<K475, status,unused,minimum symbol
Default:
10
Options:
0 to 32
status,unused,minimum length>
1 = Enabled
1
to account for a reserved space. For example, if your symbol
3
characters, set Symbol Length to 4.
Chapter 4 Symbologies
length>
MS-3 CCD Reader User's Manual
4-15
Need help?
Do you have a question about the MS-3 and is the answer not in the manual?
Questions and answers