Symbol Length #2 (Interleaved 2 of 5)
Usage:
If using a second symbol, a zero or any even symbol length in the option
range may be specified. If not using a second symbol, set Symbol
Length #2 to 0 to ensure data integrity.
Definition:
Specifies a number of characters that the reader will recognize, including
start and stop and check digit characters. The reader ignores any symbol
smaller than the specified length.
Note: If Range Mode is set to Enable, the settings for Symbol Length
#1 and Symbol Length #2 will define the range of symbol lengths that
can be decoded.
Serial Cmd:
<K472,
#1,symbol length
Default:
10
Options:
0 to 32
Rules:
See
"Symbol Length #1 (Interleaved 2 of 5)"
Important: When setting Symbol Length to any number other than 0, add
account for a reserved space. For example, if your symbol has
bol Length to 4.
status,check digit status,check digit output status,symbol length
#2>
Chapter 4 Symbologies
for rules for saving.
3
characters, set Sym-
MS-3 CCD Reader User's Manual
1
to
4-9