Decodes Before Output
Decodes Before Output
Note
When setting up, determine if the reader's scan rate is capable of scanning your
:
longest symbol the required number of times.
Usage:
This is a very useful feature to increase reliability of reads for symbolo-
gies that do not have internal error checking such as I 2/5.
Definition:
The number of decodes required per symbol before a its data is sent. It
requires the reader to successfully decode a symbol a designated number
of times before it is sent.
Serial Cmd:
<K221, number before
Default:
0
Options:
0 to 10 (0 = "auto adaptive")
If in Single symbol mode it doesn't achieve the number of required decodes during the
read cycle, a noread will be sent.
Note: Higher settings will decrease throughput speed.