Supplementals
Required (UPC/EAN)
Usage:
Reads Supplementals typically used in publications and documentation.
Definition:
A supplemental is a 2 or 5 digit symbol appended to the main symbol.
When set to Enabled (Required), the reader reads supplemental symbol
data that has been appended to the standard UPC or EAN codes.
Serial Cmd:
<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13
mentals
UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13>
Default:
Disabled
Options:
0 = Not required, but output if decoded
1 = Enabled (Required)
Supplemental 2 Status
Default:
Disabled
Serial Cmd:
<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supple-
mentals
UPC-A as EAN-13, UPC-E as A,EAN-8 as EAN-13>
Options:
0 = Disabled
Supplemental 5 Status
Default:
Disabled
Serial Cmd:
<K489,UPC-A status,UPC-E status,EAN-8 status,EAN-13 status,supple-
mentals required,supplemental 2
UPC-A as EAN-13,UPC-E as A,EAN-8 as EAN-13>
Options:
0 = Disabled
required,supplemental 2 status,supplemental 5 status,
(Not Required)
required,supplemental 2
1 = Enabled
1 = Enabled
Chapter 4 Symbologies
status,supplemental 5 status,
status,supplemental 5
MS-3 CCD Reader User's Manual
status,supple-
status,
4-13