2.7.4
Stop Valve (L9852CB, G7016XH)
This valve mounted on the calibration gas line in the system to allow for manual calibration. This
is applies to the system configuration shown for system 1 in section 1.
Standard Specifications
Connection:
Material:
Weight:
Part No.
L9852CB
G7016XH
Rc1/4 or 1/4NPT
2.7.5
Check Valve (K9292DN, K9292DS)
This valve is mounted on the calibration gas line (directly connected to the detector).
This is applied to a system based on the (System 2 and 3) system configuration .
This valve prevents the sample gas from entering the calibration gas line. Although it functions as
a stop valve, operation is easier than a stop valve as it does not require opening/closing at each
calibration.
Screw a check valve, instead of a stop valve into the calibration gas inlet of the detector.
Standard Specifications
l
Connection:
Material:
Pressure:
Weight:
Part No.
K9292DN
K9292DS
K9292DN : Rc 1/4(A),R 1/4(B)
K9292DS : 1/4FNPT(A),1/4NPT(Male)(B)
Approx. 19
Rc 1/4 or 1/4 NPT(F)
SUS 316 (JIS)
Approx. 150 g
Description
Joint: Rc 1/4, Material: SUS316 (JIS)
Joint: 1/4 NPT, Material: SUS316 (JIS)
Ø48
40
Rc1/4 or 1/4NPT(F)
SUS304 (JIS)
70 kPa G or more and 350 kPa G or less
Approx. 90 g
Description
Joint: Rc 1/4, Material: SUS304 (JIS)
Joint: 1/4 NPT, Material: SUS304 (JIS)
A
Approx. 54
<2. Specifications>
Unit: mm
F15.ai
Unit: mm
B
F2-11E.ai
IM 11M12A01-02E
2-27
16th Edition : Mar. 19, 2020-00