MAIN MACHINE (B064 SERIES/B140 SERIES/B246 SERIES)

Machine Level

1. Set a stand [A] at each corner of the
machine.
2. Place a level on the exposure glass
and use a wrench to turn each nut [B]
and level the machine to ±5 mm of the
horizontal.
3. Check the machine operation. With
the customer, determine the best
place to attach the cleaning reminder
decal.

Date/Time Setting

Use the User Tools menu to set the current date and time.
• On the operation panel, press the User Tools key.
• On the touch-panel, press "System Settings".
• Press the "Timer Setting" tab.
• Press "Set Date" the enter the date.
• Press "Set Time" to enter the time.

SP Codes

SP5812-001~002
SP5841-001
SP7825 (B064 Series Only)
Service Telephone
Number Settings
Supply Name Setting –
Toner Name Setting:
Black
Total Counter Reset
1-22
15 February 2006
[A]
Execute this SP and enter the
contact numbers of the custom
engineer. These are the
numbers displayed when a
service call is issued.
This name appears when the
user presses the Inquiry on the
User Tools screen.
Execute after installation and
after making all test copies to
reset the electronic counter
total.
[B]
B064I010.WMF