FUSING UNIT
Reinstallation
• To prevent damage to a thermostat, never touch its detection surface.
• Place the end of the thermostat harness that has the round lead [B] in between
the two bracket ribs [C].
• Tighten the screw for the round lead [B] as tight as possible without damaging
the screw or screw hole.
Important
• If the harness is not positioned between the between the bracket ribs (as shown
under "Incorrect" below), this could cause a errors (SC542 or SC545).
Correct
(C)
(A)
(B)
Incorrect
3-66
15 February 2006