SERVICE PROGRAM MODE TABLES
5816
Remote Service
001
I/F Setting
Turns the remote diagnostics off and on.
[0~2/1]
0: Remote diagnostics off.
1: Serial (CSS or NRS) remote diagnostics on.
2: Network remote diagnostics.
002
CE Call
Lets the customer engineer start or end the remote machine check with CSS or
NRS; to do this, push the center report key
003
Function Flag
Enables and disables remote diagnosis over the NRS network.
[0~1/1]
0: Disables remote diagnosis over the network.
1: Enables remote diagnosis over the network.
007
SSL Disable
Controls if RCG (Remote Communication Gate) confirmation is done by SSL
during an RCG send for the NRS over a network interface.
[0~1/1]
0: Yes. SSL not used.
1: No. SSL used.
008
RCG Connect Timeout
Sets the length of time (seconds) for the time-out when the RCG (Remote
Communication Gate) connects during a call via the NRS network.
[1~90/1 sec.]
009
RCG Write to Timeout
Sets the length of time (seconds) for the time-out when sent data is written to
the RCG during a call over the NRS network.
[0~100/1 sec.]
010
RCG Read Timeout
Sets the length of time (seconds) for the timeout when sent data is written from
the RCG during a call over the NRS network.
[0~100/1 sec.]
011
Port 80 Enable
Controls if permission is given to get access to the SOAP method over Port 80
on the NRS network.
[0~1/1]
0: No. Access denied
1: Yes. Access granted.
021
RCG – C Registed
This SP displays the Cumin installation end flag.
1: Installation completed
2: Installation not completed
022
RCG – C Registed Detail
This SP displays the Cumin installation status.
0: Basil not registered
1: Basil registered
2: Device registered
5-82
15 February 2006

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mt-c2Mt-c3

Table of Contents