Adf Input Check: Sp6007 - Ricoh MT-C1 Service Manual

Table of Contents

Advertisement

15 February 2006

5.6.3 ADF INPUT CHECK: SP6007

1. Open SP mode SP6007.
2. Select the SP number that corresponds to the component you wish to check.
(Refer to the table below.)
3. Press On then press Off to test the selected item. You cannot exit and close
this display until you click Off to switch off the output check currently executing.
Bit
7 6 5 4 3 2 1 0
Data
1 1 0 0 1 0 1 0
Group 1
No.
0
Original Length Sensor 3 (LG)
1
Original Length Sensor 2 (A4)
2
Original Length Sensor 3 (B5)
3
Original Set Sensor
4
Original Width Sensor 1
5
Original Width Sensor 2
6
Original Width Sensor 3
7
Original Width Sensor 4
Group 2
No.
0
Skew Correction Sensor
1
Interval Sensor
2
Registration Sensor
3
Exit Sensor
4
DF Position Sensor
5
APS Start Sensor
6
Feed Cover Sensor
7
Pick-up Roller HP Sensor
Group 3
No.
0
Bottom Plate HP Sensor
1
Bottom Plate Position Sensor
2
Not Used
3
Not Used
4
Not Used
5
Not Used
6
Not Used
7
Not Used
Description
Description
Description
5-197
INPUT/OUTPUT CHECK