15 February 2006
DEVELOPMENT AND TONER SUPPLY
6.9.9 TONER BOTTLE SUPPLY AND VENTILATION
[C]
[A]
[B]
B246D932.WMF
[D]
B246D933.WMF
The toner supply motor [A] (a dc motor) and gears [B] rotate the toner bottle [C].
The toner cooling fan [D] (below the operation panel) ventilates the area around the
bottle. This fan always switches off and on with the polygonal mirror motor.
6-73