Configuring An Uplink Policy For The Customer-Side Port; Configuring An Uplink Policy For The Network-Side Port - H3C S3600V2 SERIES Layer 2-Lan Switching Configuration Manual

Hide thumbs Also See for S3600V2 SERIES:
Table of Contents

Advertisement

Task
Configuring an uplink policy for the
network-side port
Configuring a downlink policy for the
customer-side port
Configuring the customer-side port
Configuring the network-side port

Configuring an uplink policy for the customer-side port

The uplink policy on the customer-side port modifies the SVLAN ID of incoming traffic.
To configure an uplink policy for the customer-side port:
Step
1.
Enter system view.
2.
Create a class and enter class
view.
3.
Specify a foreign CVLAN as a
match criterion.
4.
Specify a foreign SVLAN as a
match criterion.
5.
Return to system view.
6.
Create a traffic behavior and enter
traffic behavior view.
7.
Configure an SVLAN marking
action to replace the foreign
SVLAN ID with a local SVLAN ID.
8.
Return to system view.
9.
Create a QoS policy and enter
QoS policy view.
10.
Associate the class with the
behavior.

Configuring an uplink policy for the network-side port

The uplink policy on the network-side port modifies the CVLAN ID of incoming traffic.
To configure an uplink policy for the network-side port:
Step
1.
Enter system view.
Description
Replaces foreign CVLANs with local CVLANs for uplink traffic
(required).
Replaces local SVLANs and CVLANs with foreign SVLANs and
CVLANs (required).
Configures VLAN and other settings required for two-to-two VLAN
mapping (required).
Configures VLAN and other settings required for two-to-two VLAN
mapping (required).
Command
system-view
traffic classifier tcl-name
[ operator and ]
if-match customer-vlan-id
vlan-id
if-match service-vlan-id
vlan-id
quit
traffic behavior
behavior-name
remark service-vlan-id
vlan-id
quit
qos policy policy-name
classifier tcl-name behavior
behavior-name
Command
system-view
213
Remarks
N/A
Repeat these steps to create one
class for each foreign CVLAN and
SVLAN pair.
Repeat these steps to configure one
SVLAN marking action for each
CVLAN and SVLAN pair.
N/A
Repeat this step to create other
class-behavior associations.
Remarks
N/A

Advertisement

Table of Contents
loading

Table of Contents