HUAWEI NetEngine5000E Core Router
Configuration Guide - System Management
As shown in
across a public network. According to the network planning, NMS2 can manage every MIB
object except HGMP on the router, and NMS1 does not manage the router.
On the router, only the modules that are enabled by default are allowed to send alarms to NMS2.
This prevents an excess of unwanted alarms from being sent to NMS2. Excessive alarms can
make fault location difficult. Informs need to be used to ensure that alarms are received by NMS2
because alarms sent by the router have to travel across the public network to reach NMS2.
Contact information of the equipment administrator needs to be configured on the router. This
helps the NMS administrator to contact the equipment administrator if a fault occurs.
Figure 3-8 Networking diagram for configuring a device to communicate with an NM station
by using SNMPv2c
1.1.1.1/24
1.1.1.2/24
Configuration Roadmap
The configuration roadmap is as follows:
1.
2.
3.
4.
5.
6.
Data Preparation
To complete the configuration, you need the following data:
l
l
l
l
l
Issue 01 (2011-10-15)
Figure
3-8, two NM stations (NMS1 and NMS2) and the router are connected
NMS1
IP Network
NMS2
Enable the SNMP agent.
Configure the router to run SNMPv2c.
Configure an ACL to allow NMS2 to manage every MIB object except HGMP on the
router.
Configure the router to send informs to NMS2 to ensure alarm sending reliability.
Configure the contact information of the equipment administrator.
Configure NMS2.
SNMP version
Community name
ACL number
IP address of the NM station
Contact information of the equipment administrator