HUAWEI NetEngine5000E Core Router
Configuration Guide - System Management
In practice, you can run this command in any view to view basic information about the device.
slot-id specifies the slot ID of a module.
l Choose a board in a certain slot and view basic information about this board.
l Run the display device pic-status command to view basic information about the sub-cards
----End
1.4.3 Checking Memory Usage
By checking memory usage, you can view the current resource usage of the device.
Procedure
Step 1 Run the display memory-usage [ threshold ] [ slave | slot slot-id ] command to check the
memory usage of the MPU or LPU.
----End
1.4.4 Checking CPU Usage
By checking CPU usage, you can view the current resource usage of the device.
Procedure
Step 1 Run the display cpu-usage[ configuration ] [ slave | slot slot-id ] command to check the CPU
usage of an MPU or an LPU.
----End
1.4.5 Checking Device Temperatures
By checking device temperatures, you can view the current temperature status, temperature
alarm threshold, and actual temperature of each board.
Procedure
Step 1 Run the display temperature [ lpu [ slot slot-id ] | mpu | sfu | slot slot-id ] command to view
the working temperature of a board.
To view the working temperature of each board on the router, you can run the display
temperature command.
In practice, you can run the display temperature command in any view to view the current
working temperatures of the router. The temperature information includes the following
contents:
Issue 01 (2011-10-15)
of each LPU on the router.
NOTE
To set the threshold of the memory usage of the MPU or LPU, you can run the set memory-usage
threshold threshold-value [ restore restore-threshold-value ] [ slave | slot slot-id ] command.
NOTE
To set the threshold of the CPU usage of the MPU, you can run the set cpu-usage threshold threshold-
value [ restore restore-threshold-value ] [ slave | slot slot-id ] command.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
1 Device Management
6
Need help?
Do you have a question about the NetEngine5000E and is the answer not in the manual?