Collecting statistics about MPLS original flows can obtain flow information corresponding to
a specified label.
Networking Requirements
On a single NE5000E, an interface is numbered in the format of slot number/card number/
interface number. On the NE5000E cluster, an interface is numbered in the format of chassis
ID/slot number/card number/interface number. If the slot number is specified, the chassis ID of
the slot must also be specified.
As shown in
the IGP protocol on the MPLS backbone network.
Local LDP sessions are established between Router A and Router B, and between Router B and
Router C. A remote LDP session is established between Router A and Router C. NetStream is
enabled on Router B to collect statistics about MPLS flows.
Figure 6-15 Networking diagram of collecting statistics about MPLS original flows
Loopback1
1.1.1.9/32
Configuration Roadmap
The configuration roadmap is as follows:
Issue 01 (2011-10-15)
#
ip netstream aggregation as
enable
export version 9
ip netstream export source 3.3.3.1
ip netstream export host 2.2.2.1 3000
#
return
CAUTION
Figure
6-15, Router A, Router B, and Router C support MPLS and use OSPF as
POS1/0/0
10.1.1.1/24
POS1/0/0
10.1.1.2/24
RouterA
CE1
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
Loopback1
2.2.2.9/32
POS2/0/0
10.1.2.1/24
POS1/0/0
RouterB
10.1.2.2/24
6 NetStream Configuration
Loopback1
3.3.3.9/32
192.168.1.2/24
GE1/0/0
192.168.1.1/24
RouterC
NSC&NDA