BPM Warning Level and Required Procedures
In the Regeneration Inhibit Mode, the buzzer starts sounding and the indicator display changes in response to the PM level
in order to prompt the operator to perform the required procedure listed below.
A Once the regeneration level has been reached, immediately perform the required procedure for regeneration.
Interrupting the regeneration cycle or continued operation by ignoring the warning signs may cause DPF and engine
damage.
1
PM warning level:
Buzzer: Not sounding
2-1
PM warning level:
Buzzer: Sounding every
5 seconds
2-2
PM warning level:
Buzzer: Sounding every
3 seconds
3
PM warning level:
Buzzer: Sounding every
1 second
Engine output: 50%
4
PM warning level:
Buzzer: Sounding every
1 second
Engine output: 50%
Regeneration Inhibit Mode
DPF system status
The regeneration indicator starts
flashing.
At PM warning levels range from 1 to 2-2, it is also possible to change DPF INHIBIT
switch to auto regeneration mode then perform regeneration.
The regeneration indicator starts
flashing.
The Parked regeneration indicator
starts flashing.
If the parked regeneration cycle is interrupted or the tractor is continuously operated in the PM
warning level 2:
The engine warning indicator starts
flashing.
The parked regeneration indicator starts
flashing
If the regeneration cycle is interrupted or the tractor is continuously operated ignoring the
warning signs, in the PM warning level 3:
The engine warning indicator remains
constantly "ON".
OPERATING THE ENGINE
Required procedure
A specific level of PM has built up in the
DPF muffler.
Continue with the operation as it is.
Move the tractor to a safe area, then follow
the "Operating Procedure for Parked
Regeneration".
Immediately stop working the tractor, move
the tractor to a safe area, then follow the
"Operating Procedure for Parked
Regeneration".
If the tractor is operated further and the
operator ignores the warning signs, then
regeneration will be disabled.
Immediately move the tractor to a safe
place and place in park, turn "OFF" engine.
Contact your local KUBOTA Dealer.
A At this level never continue to operate
the tractor, otherwise damage may
result to the DPF and engine.
25