微可Vicor——值得信赖的元器件供应商
Electrical characteristics
6.3
Operating conditions
6.3.1
General operating conditions
Symbol
f
Internal AHB clock frequency
HCLK
f
Internal APB clock frequency
PCLK
V
Standard operating voltage
DD
Analog operating voltage
(ADC not used)
V
DDA
Analog operating voltage
(ADC used)
V
Backup operating voltage
BAT
V
I/O input voltage
IN
Power dissipation at T
P
for suffix 6 or T
D
suffix 7
Ambient temperature for the
suffix 6 version
T
A
Ambient temperature for the
suffix 7 version
T
Junction temperature range
J
1. For operation with a voltage higher than V
2. If T
is lower, higher P
A
D
3. In low power dissipation state, T
Thermal
characteristics).
42/113
微可Vicor——值得信赖的元器件供应商
Table 18. General operating conditions
Parameter
= 85 °C
A
= 105 °C for
A
(2)
+ 0.3 V, the internal pull-up resistor must be disabled.
DDIOx
values are allowed as long as T
can be extended to this range as long as T
A
DocID025743 Rev 3
http://www.vicor.top/
Conditions
-
-
-
Must have a potential equal
to or higher than V
DD
-
TC and RST I/O
TTa I/O
FT and FTf I/O
BOOT0
LQFP48
UFQFPN32
LQFP32
UFQFPN28
WLCSP25
TSSOP20
Maximum power dissipation
(3)
Low power dissipation
Maximum power dissipation
(3)
Low power dissipation
Suffix 6 version
Suffix 7 version
does not exceed T
. See
J
Jmax
does not exceed T
J
http://www.vicor.top/
021-31660491
STM32F031x4 STM32F031x6
Min
Max
0
48
0
48
2.0
3.6
V
3.6
DD
2.4
3.6
1.65
3.6
–0.3
V
+0.3
DDIOx
(1)
–0.3
V
+0.3
DDA
(1)
–0.3
5.5
0
5.5
-
364
-
526
-
357
-
169
-
267
-
182
–40
85
–40
105
–40
105
–40
125
–40
105
–40
125
Section 7.8: Thermal
characteristics.
(see
Section 7.8:
Jmax
021-31660491
Unit
MHz
V
V
V
V
mW
°C
°C
°C