Group 23: TORQUE and CURRENT LIMITS

[SPC_TORQ_MAX]
Input of TORQUE/CURRENT_LIMITATION-function block.
Maximum torque limit for the speed controller.
Can be connected to analog input or function block output.
2301
FB_I: C4
[SPC_TORQ_MIN]
Input of TORQUE/CURRENT_LIMITATION-function block.
Minimum torque limit for the speed controller.
Can be connected to analog input or function block output.
2302
FB_I: C4
[TREF_TORQ_MAX]
Input of TORQUE/CURRENT_LIMITATION-function block.
Maximum torque limit for the torque reference chain.
Can be connected to analog input or function block output.
2303
FB_I: C4
[TREF_TORQ_MIN]
Input of TORQUE/CURRENT_LIMITATION-function block.
Minimum torque limit for the torque reference chain.
Can be connected to analog input or function block output.
2304
FB_I: C4
TORQ_MAX
Parameter of TORQUE/CURRENT_LIMITATION-function block.
Maximum torque limit for the drive.
2305
FB_P: I2
TORQ_MIN
Parameter of TORQUE/CURRENT_LIMITATION-function block.
Minimum torque limit for the drive.
2306
FB_P: I2
ARM_CURR_LIM_P
Parameter of TORQUE/CURRENT_LIMITATION-function block.
Maximum current of the motor bridge.
2307
FB_P: I2
ARM_CURR_LIM_N
Parameter of TORQUE/CURRENT_LIMITATION-function block.
Maximum current of the generator bridge.
2308
FB_P: I2
SC: TORQ
HL: 19999
SC: TORQ
HL: 19999
SC: TORQ
HL: 19999
SC: TORQ
HL: 19999
SC: TORQ
HL: 16000
SC: TORQ
HL: -20
SC: MCURR HL: 16383
SC: MCURR HL: 0
DCS500 Pin and Parameter list
LL: 0
D: 12510
LL: 0
D: 12511
LL: 0
D: 12510
LL: 0
D: 12511
LL: 20
D: 4000
LL: -16000
D: -4000
LL: 0
D: 4095
LL: -16383
D: -4095
( S6/16 )
U: -
( S6/16 )
U: -
( S6/16 )
U: -
( S6/16 )
U: -
( S6/16 )
U: %
( S6/16 )
U: %
( S6/16 )
U: A
( S6/16 )
U: A
A 57