BC-Logic
Input of 12-PULSE LOGIC-function block
In conjunction to input INHIB_LOGIC the converters now exchange the logic level of bit 5
of the signal BC (11209). This bit blocks or releases the current controler. Using this input
for the data exchange gives the fastest reaction available. The use of bit 5 of the signal BC
is recommended, if the 12 pulse system needs redundancy. In this case, the ON/OFF and
the RUN command has to be given to each of the converters via digital inputs depending
on the converter needed. This enables the user to use both converters in a 12 pulse mode
or having the Master or the Follower running as a stand alone drive.
Interconnection:
-
At systems, running in 6 or 12 pulse mode (redundancy; Master and Follower used in
12 pulse mode or only the Master is used in single 6 pulse mode or only the Follower
is used in single 6 pulse mode), connect this input to the output INPUT_X18:15
(13619) at both converters, the Master and the Follower.
3616
FB_I: C4

Group 37: WINDER PARAMETER

3701-3726: Parameters for application winder blocks
See application function block data sheets.

Group 38: FUNCTION BLOCKS WINDER

3801-3867: Function for application winder
See application function block data sheets.

Group 39: FUNCTION BLOCKS 10

3901-3988: Parameter for application function blocks
See application function block data sheets.
SC:
HL: 19999
-
DCS500 Pin and Parameter list
LL: 0
D: 0
(S13/16 ).
U: -
A 66